section 3
3.4

connections

There are two cables connected to the Plasmas Gas Box: one is 24V power, the other is CAN. There are four gas
inputs (Argon, H35, PG1 and PG2) and one gas output (PG). The gas fittings are listed below.
inputs
output
3.5

troubleshooting

The Plasma Gas Box has two visible LEDs that indicate its' status. When the GREEN LED is on, this indicates power
is applied to the unit and the rate at which it is flashing shows the operational status of the unit (refer to the chart
below). If the Green LED is not ON, check the power cable, which should carry 24VDC and 24VAC from the Shield
Gas Box.
If the Yellow LED is not ON, either there is no power to the unit or the station is not selected.
The Plasma Gas Box is highly integrated and is treated as a "Black Box". If one or more functions of the unit stop
working, the unit must be returned for repair. Contact technical support for troubleshooting and RMA assis-
tance.
leD
green
Yellow
Chassis must be connected to the machine ground.
gas
Argon
1/8" NPT x "A" Inert Gas RH Female
H-35
1/4" NPT x "B" Fuel LH Male
PG1
1/4" NPT x "B" Inert Gas RH Female
PG2
1/4" NPT x "B" Oxygen RH Male
PG
status
OFF
10% ON, 90% OFF
50% ON, 50% OFF
90% ON, 10% OFF
ON
note:
fitting
Connection, Male
0.125NPT to "A" Size
Boot loader is running
Application is running
Application is running, CAN is available
Station is selected
35
plasma gas Box
esaB
p/n
631475
83390
74S76
83389
2064113
meaning
Power OFF