6.16

torch Body maintenance

Inspect O-rings daily and replace if damaged or worn.
Apply a thin coat of silicone grease to O-rings before assembling torch. This facilitates easy future
assembly and disassembly for service.
O-ring (1.61" (41mm) I.D. x .07" (1.8mm) BUNA-70A) p/n 996528.
Warning
Keep electrical contract ring contact points free of grease and dirt.
Inspect ring when changing nozzle.
Clean with cotton swab dipped in isopropyl alcohol.
electric shocK can Kill!
Before performing torch maintenance:
Turn power switch of the power source console to the OFF posi-
tion
Disconnect primary input power.
Contact Ring Screw
pt-36 plasma torch
O-Ring locations
Contact Ring Points
Contact Ring Points
79
Contact Ring