Troubleshooting; Replacement Parts - ESAB m3 G2 System Manual

Plasma system
Table of Contents

Advertisement

section 2
2.5

troubleshooting

On the Shield Gas Box, there are two LEDs displaying the status of the CAN-bus module. The states of these lights
are shown in the table below.
leD
green
Yellow
In normal operation, the green LED indicating the power must be ON. When the station is selected, the yellow
LED should be ON all the time; and green LED will flash 90% ON and 10% OFF. Otherwise, there is a problem.
1. If the green light is not on, check the power input (cale connection) and fuse.
2. If the yellow light is not on and the green light is on, check can-bus connection. Make sure the sta-
tion is selected.
2.6

replacement parts

The Shield Gas Box is highly integrated and only a few parts can be replaced by a qualified service engineer or
by the customer. These parts are listed below. Otherwise, the entire Shield Gas Box needs to return for repair. It
is recommended that customers contact Technical Support before attempting repairs on these units.
item no.
status
OFF
10% ON, 90% OFF
50% ON, 50% OFF
90% ON, 10% OFF
ON
Description
1
Transformer
2
3
Fuse - T630mA 250V, 5 x 20mm
4
Solenoid 6240 for Air Curtain
5
Pressure Gauge
6
Pressure Regulator
Boot loader is running
Application is running
Application is running, CAN is available
Station is selected
Fan
26
shielD gas Box
meaning
Power OFF
esaB pn
0558008612
0558008614
0558008613
0558008615
0558008616
0558008617