Removal And Replacement Of The Torch Body - ESAB m3 G2 System Manual

Plasma system
Table of Contents

Advertisement

section 6
6.17

removal and replacement of the torch Body

Warning
1. Loosen the worm gear hose clamp so that the torch sleeving can be freed and pulled back up the cable
bundle. Approximately 7 inches should be far enough. Unscrew the torch sleeve and slide it back until the
pilot arc connection is exposed.
Handle
2. Disconnect the power cables which are threaded onto the shorter stems at the back of the torch. Note that
one of these connections is left-handed. Unscrew the gas hoses from the torch head assembly by using a
7/16" (11.1mm) and a 1/2" (12.7mm) wrench. Removal of the gas hoses is easier if the power cables are re-
moved first.
7/16" plasma gas
connection
electric shocK can Kill!
Before performing torch maintenance:
Turn power switch of the power source console to the OFF position
Disconnect primary input power.
1/2" shield gas
connection
pt-36 plasma torch
80
Torch Body
1/2" power cable
connections