section 6
5. If the electrode holder did not come out in step 3, remove the electrode holder from torch body using the
Electrode Holder Removal Tool. The hex on the end of the electrode holder removal tool will engage in a hex
in the holder.
8. Disassemble electrode holder and gas baffle. Carefully remove O-ring from electrode holder and slide baffle
from holder. Inspect nozzle seating surface (front edge) for chips. Look for cracks or plugged holes. Do not
attempt to clear holes. Replace baffle if damaged.
Check all O-rings for nicks or other damage that might prevent O-ring from forming a gas/water
Torch Body
Electrode Holder
Electrode Holder Removal Tool
note:
tight seal.
O-ring (located behind baffle)
Gas Baffle
76
pt-36 plasma torch
Electrode Holder