Download Print this page

General Description; Hardware Specifications; Electronic Specifications - Assa Abloy SARGENT IN120 Installation Instructions Manual

Exit device
Hide thumbs Also See for SARGENT IN120:

Advertisement

IN120 Exit Device

General Description

2
The IN120 WiFi lock offers the ease and flexibility of WiFi in a streamlined design, setting a new standard for
aesthetics and performance. The IN120 uses IEEE 802.11 WiFi communication and a flexible feature set for
easier, more cost-effective installations, allowing facilities to leverage their IT infrastructure to expand access
control coverage to more doors. Featuring HID
security and multiple credentials, including mobile access. SARGENT exit devices are designed with quality
components to provide high security, performance and durability.

Hardware Specifications

3
Complete lockset with on-board memory
multiCLASS SE reader and/or keypad
ADA compliant
Outside lever is unlocked through access
control credentials only
May be used for indoor and outdoor applications
Exit Device always allows immediate egress
NOTE: A weather-protective gasket is required for outdoor applications.
IN120 Rim Exit
Latch – 3/4" throw, stainless steel
Accepts all SARGENT rim cylinders (8877 only)
Key override standard with 8877
(#34 rim cylinder supplied)

Electronic Specifications

4
• HID
multiCLASS SE
®
support for the following credentials:
2.4 GHz credential compatibility:
Secure Identity Object
Mobile IDs (Bluetooth Smart)
13.56 MHz credential compatibility:
iCLASS
iCLASS SE
iCLASS Seos
SIO on MIFARE
SIO on MIFARE
MIFARE
DESfire
NFC-enabled mobile phones
125 kHz credential compatibilty:
HID Prox
!
*To comply with "Fire Listed" doors, the batteries
must be replaced with alkaline batteries only.
technology offers
®
(SIO) on
®
(SIO-enabled)
®
®
Classic
®
DESfire
EV1
®
®
Classic
®
EV1
®
®
multiCLASS SE™ technology, it supports heightened identity
®
UL Listed for panic and available UL Listed for
fire-rated openings (12- option)
SARGENT exit devices furnished for 1-3/4"
standard (specify 31- and thickness for
thicker doors)
ANSI/BHMA A156.25 Listed Grade 1 Compliant
Available with ET Trim only
(many lever designs available)
IN120 Mortise Exit
Latch – 3/4" throw, anti-friction, brass
Key override standard with 8977
[#46 (1-3/4") mortise cylinder supplied]
• Multiple time zone and holiday access scheduling
• First-in unlock or automatic unlock configuration,
based on specified time schedule
• 2,400 users per lock; 10,000 event audit trail
• Privacy button
Power Requirements:
Alkaline AA Batteries: 9V, 300mA
Optional Hard Power
(UL294 Listed Power Supply Required):
9-24VDC, 300mA
• UL Listed - UL 294 Indoor Use
• CUL Listed - S319: Class 1
• UL 294 Access Control Performance Ratings:
Destructive Attack
Line Security
Endurance
Standby Power
3
1-800-810-WIRE • www.sargentlock.com • A8185A
Level I
Level I
Level IV
Level I

Hide quick links:

Advertisement