IN120 Exit Device
3 Mount Mortise & Exit Device Chassis
1. Slide mortise lock into door and loosely secure with (2) flat head screws.
NOTE: Exit chassis harness consists of a 6-pin female connector and
ground lug (Fig. 3A)
2. Feed 6-pin connector and larger ground lug straight through to outside
of door (Fig. 3A, B) while feeding smaller ground lug into wire hole, up
through wire channel and out through inside of door (Fig. 3A).
DO NOT PINCH THE WIRE HARNESS.
3. Begin to secure the exit chassis with through bolts
to the ET trim using (2) 1/4 -20 x 2-3/8"
flat head machine screws.
Inside of Door
(2) 1/4 x 2-3/8"
Flathead Machine
Screws (secures ET)
Exit Chassis
Fig. 3A
Fig. 5