Rxe Cabling - IBM eserver xSeries 440 8687 Hardware Maintenance Manual

Hide thumbs Also See for eserver xSeries 440 8687:
Table of Contents

Advertisement

RXE cabling

The cabling to an RXE100 Expansion Enclosure should be as follows:
Primary Port A to Secondary Port A
Primary Port B to RXE100 Side A
Secondary Port B to RXE100 Side B
These connections can be verified with the following display (from the diagnostic
program main menu, select "Hardware Info" and "Summit Chips"). The primary
display in the following example begins with "Memory":
In line number 12, Port A is shown as "Ready", but the "Connected_to" is unknown.
In line number 10, Port B is shown as "Connected_to" RXE100 Side A, Port A.
In line number 16, Port 1 is the internal port connecting to Side B, and it is
"Ready".
=================================================================================
This_______
Connectd_to
no
Chip_._Port
Chip_._Port
--
-----------
-----------
Memory:
07
Memory_1.P0
PCI-X__1.P0
08
Memory_1.P1
PCI-X__2.P0
09
Memory_2.P0
PCI-X__2.P1
10
Memory_2.PB
RXE100_A.PA
PCI-X:
11
PCI-X__1.P0
Memory_1.P0
12
PCI-X__1.PA
...........
13
PCI-X__2.P0
Memory_1.P1
14
PCI-X__2.P1
Memory_2.P0
RXE100:
15
RXE100_A.PA
Memory_2.PB
16
RXE100_A.P1
...........
================================================================================
Ext Is
Has
Port
Int Ready Cable Speed
--- ----- ----- -----
Int
yes
yes
1000 MHz
Int
yes
yes
500 MHz
Int
yes
yes
500 MHz
Ext
yes
yes
500 MHz
Int
yes
yes
1000 MHz
Ext
yes
yes
250 MHz
Int
yes
yes
500 MHz
Int
yes
yes
500 MHz
Ext
yes
yes
500 MHz
Int
yes
yes
250 MHz
Trans Recei Error
Error Error Count
----- ----- -----
no
no
00
no
no
00
no
no
00
no
no
00
no
no
00
no
no
00
no
no
00
no
no
00
no
no
00
no
no
00
63
Diagnostics

Advertisement

Table of Contents
loading