10. Use the arrow keys to select Exit Utility from the menu or press Esc to close
11. Remove the diskette from the diskette drive. The server restarts automatically.
38
xSeries 440 Type 8687: Hardware Maintenance Manual
Note: The values in the window are only examples; your settings might be
different.
5. Use the arrow keys to navigate to each field. Verify the values in the following
fields:
Network Interface
The default is Disabled. Change this field to Enabled.
IP Address
The default value is 192.96.1.1. You can use the default value or
another value, but the server must be able to establish a connection to
that address. The default IP address (local and remote) is easily
reconfigurable.
Subnet Mask
The default value is 255.255.255.255.
Line Type
The value is set to PPP.
Remote IP Address
The default value is 192.96.1.2.
Authentication Protocol
The default is CHAP then PAP. Make sure that the value in this field
matches your client settings.
For detailed information about the PPP settings, see the information about
configuring PPP access over a serial port in the Remote Supervisor Adapter
User's Guide on the IBM Documentation CD.
6. Press F6 to apply the changes.
7. Press Esc. After the Warning window opens, press Enter to restart the Remote
Supervisor Adapter.
8. Press Esc to return to the Configuration Settings window. If you need to
configure the serial port, go to "Configuring the serial port for text-based
remote access" on page 36.
9. Press Esc to return to the Utility program main window.
the Utility program.