Error code/symptom
162 (Device Configuration Error)
Note: Be sure to load the default settings and
any additional desired settings; then, save
the configuration
163 (Real-Time Clock error)
164 (Memory configuration changed, see
"Memory settings" on page 18.)
175 (Hardware error)
177, 178 (Security hardware error)
184 (Power-on password corrupted)
185 (Drive startup sequence information
corrupted)
186 (Security hardware control logic failed)
187 (VPD serial number not set.)
188 (Bad EEPROM CRC #2)
189 (An attempt was made to access the
server with invalid passwords)
201 (memory controller test)
289 (DIMM has been disabled by the user or
system, see "Memory settings" on page 18.)
301 (Keyboard or keyboard controller error)
Note: After installing a USB keyboard, you
might need to use the Configuration/Setup
Utility program to enable keyboardless
operation and prevent the POST error
message 301 from being displayed during
startup.
182
xSeries 440 Type 8687: Hardware Maintenance Manual
FRU/action
1. Run Configuration/Setup
2. Battery
3. Failing device
4. I/O board
1. Run Configuration/Setup.
2. Battery.
3. I/O board.
1. Run Configuration/Setup.
2. DIMM.
3. SMP board.
1. SMP board
2. I/O board
3. Service processor
1. Run Configuration/Setup.
2. I/O board.
3. Service processor.
1. Run Configuration/Setup.
2. Battery.
3. I/O board.
1. Run Configuration/Setup.
2. I/O board.
1. Run Configuration/Setup.
2. I/O board.
3. Service processor.
1. Set serial number in Setup.
2. I/O board.
3. Service processor.
1. Run Configuration/Setup.
2. I/O board.
3. Service processor.
v Run Configuration/Setup, enter the administrator password.
1. DIMM
2. SMP board
1. Run Configuration/Setup, if disabled by user.
2. Disabled DIMM, if not disabled by user.
1.
Keyboard
2. Centerplane
3. I/O board