IBM eserver xSeries 440 8687 Hardware Maintenance Manual page 184

Hide thumbs Also See for eserver xSeries 440 8687:
Table of Contents

Advertisement

Error code/symptom
201-XXX-Y34 (Multiple DIMM failure in Port
2 Bank 4; see "DIMM removal and
replacement" on page 93)
Note: Y = SMP Board [0=Bottom SMP
Board; 1=Top SMP Board]
202-xxx-00n (Failed System Cache test)
203-xxx-xxx (Failed External Cache test)
204-198-0xx (Test Aborted)
Note: xx=SMP Board (01=Bottom SMP
Board; 10=Top SMP Board; 11=Bottom
SMP Board and Top SMP Board)
204-210-0xx (Test Failed)
Note: xxx=SMP Board (01=Bottom SMP
Board; 10=Top SMP Board; 11=Bottom
SMP Board and Top SMP Board)
206-xxx-000 (Failed Diskette Drive test)
215-xxx-000 (Failed CD-ROM test)
217-xxx-000 (Failed BIOS Fixed Disk test)
Note: If RAID is configured, the fixed disk
number refers to the RAID logical array.
217-xxx-001
Note: If RAID is configured, the fixed disk
number refers to the RAID logical array.
217-xxx-002 (Failed BIOS Fixed Disk test)
Note: If RAID is configured, the fixed disk
number refers to the RAID logical array.
217-xxx-003 (Failed BIOS Fixed Disk test)
Note: If RAID is configured, the fixed disk
number refers to the RAID logical array.
217-xxx-004 (Failed BIOS Fixed Disk test)
Note: If RAID is configured, the fixed disk
number refers to the RAID logical array.
217-xxx-005 (Failed BIOS Fixed Disk test)
Note: If RAID is configured, the fixed disk
number refers to the RAID logical array.
217-xxx-006 (Failed BIOS Fixed Disk test)
Note: If RAID is configured, the fixed disk
number refers to the RAID logical array.
172
xSeries 440 Type 8687: Hardware Maintenance Manual
FRU/action
1. Isolate failing DIMM:
a. Replace a DIMM in bank with a "known good" DIMM.
b. Rerun memory diagnostic for the failing bank on failing SMP
Board.
c. If test fails, mark replaced DIMM as "good" DIMM.
d. If test passes, mark replaced DIMM as "bad" DIMM.
e. If DIMM tested is "bad", remove it and replace it.
f. If DIMM tested is "good", do not replace it.
2. Repeat steps 1a through 1f with other DIMMs in failing bank until
error is fixed.
3. If error is not fixed, replace SMP Board Y.
1. Microprocessor n
2. SMP board
1. Reload BIOS code.
2. SMP1 board (bottom).
1. Run Quick Memory Diagnostic All Banks.
2. System BIOS problem; see PCDR log.
3. SMP Board xx.
1. Run Quick Memory Diagnostic All Banks.
2. If test runs without failure, reload system BIOS.
3. SMP Board xx.
1. Diskette drive
2. Media Bay card
1. CD-ROM drive
2. Media Bay card
v Hard disk drive 1
v Hard disk drive 2
v Hard disk drive 3
v Hard disk drive 4
v Hard disk drive 5
v Hard disk drive 6
v Hard disk drive 7

Advertisement

Table of Contents
loading

Table of Contents