General Description; General Information; Safety Instructions; Transport And Storage - iDM AERO ILM 2-7 Technical Documentation Installation Instructions

Modulation air-water-heat pumps for indoor installation, with navigator 2.0 control
Hide thumbs Also See for AERO ILM 2-7:
Table of Contents

Advertisement

1. General description

1. General description

1.1. General information

By purchasing this system you have decided in favor
tinuous quality controls and improvements as well as
functional checks at our production facilities guaran-
tee technically error-free equipment.
Please read this documentation carefully. It con-
tains important instructions for a correct installa-
tion, for the reliable and an economical operation
of the system.

1.2. Safety instructions

Installation and maintenance operations can be as-
sociated with dangers resulting from high system
pressures, high temperatures and voltaged parts.
Heat pumps may only be installed by competent spe-
cialist and exclusively put into operation by a cus-
tomer service specialist trained for that purpose by
IDM-Energiesysteme GmbH.
If maintenance work is being done on the heat pump,
disconnect the system and ensure that it is volt-free
and provided with a safeguard to prevent unintention-
al restarting. Furthermore all safety instructions in the
respective documentation or on instruction plates af-
safety regulations shall be observed.

1.3. Transport and storage

In transporting the heat pump ensure that it is never
tilted by more than 30°. Do not remove the transport
packaging until the heat pump has reached its instal-
lation location. Heat pump components must not be
stored outside. Heat pumps must not be stored in
humid rooms or dusty environments. The transport
instructions are used to transport the heat pump
transporting the components with a crane or similar
hoisting equipment.
4

1.4. Sound emission

AERO heat pumps run extremely smoothly due to
-
their construction. It is nevertheless important to
ensure that the heating room is located beyond the
noise-sensitive living area and furnished with a well-
closing door.
1.5.
Floor screed heating with the heat pump can only
take place if the air suction temperature continuously
the air evaporator cannot be guaranteed due to the
has to be heated with the electric heating element!

1.6. Service and maintenance

Regular maintenance as well as an inspection and
maintenance of all important system components
guarantees a reliable and low-price operation of the
system in the long term. We recommend you to sign
a maintenance contract with your competent cus-
tomer service.

1.7. Cleaning

If necessary, the AERO heat pump can be cleaned
using a moist cloth. The use of cleaning agents is not
recommended.
The air vent package in the air heat exchanger
has to be inspected regularly and cleared of any im-
purities (e.g. leaves,...), if necessary.
opening the tube clamp on the condensate bin. Now
the bin and the tube can be inspected and cleaned.
Installation instructions AERO ILM
heating
To prevent water damage, the conden-
sate bin and the condensate hose have
to be checked regularly for contamination.
(C) IDM ENERGIESYSTEME GMBH