iDM AERO ILM 2-7 Technical Documentation Installation Instructions page 32

Modulation air-water-heat pumps for indoor installation, with navigator 2.0 control
Hide thumbs Also See for AERO ILM 2-7:
Table of Contents

Advertisement

5. General description
Installation
5.10.2. Mounting of straight air duct
Air intake side same as the corner installation.
mounted on the duct again.
On the heat pump side, the duct, together with the
exhaust panel, is mounted in the frame of the heat
pump by the 4 supplied screws.
together with the 4 supplied screws to the duct wall
connection piece.
(duct wall connection) lies in front of the wall. At the
which ensures the stability of the wall socket.
32
Installation instructions AERO ILM
After the duct is installed, it must be insulated with
the supplied insulation. Then the wall connection duct
air duct
special foam
to seal
On the outside of the wall, the weather shield grille
(or mesh grille) is mounted directly to the insulation
of the wall opening by means of the provided dowels.
Finally, the foamed area of the wall breakthrough
must be covered with the panel
wall connection
duct
Weather-
shield grille
(C) IDM Energiesysteme GmbH
insulation

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aero ilm 4-13