iDM AERO ILM 2-7 Technical Documentation Installation Instructions page 43

Modulation air-water-heat pumps for indoor installation, with navigator 2.0 control
Hide thumbs Also See for AERO ILM 2-7:
Table of Contents

Advertisement

5.13.3.
air outlet upwards
Air inlet side
Procedure as in corner installation
Outlet panel:
The top cover panel of the AERO ILM must be re-
moved. For this, the side panels must be dismounted.
Then, on each side, two screws must be loosened
under the insulation. After that, the heatpump top-
cover can be removed.
When inserting the new blowout element upwards,
care must be taken to ensure that the insulation of the
panel is neatly closed. Then tighten the screws again.
When replacing the panel, ensure that
the insulation of the cover is cleanly
closed at all times. If this is not the case,
condensation can occur on the heat
pump cover and also on the remaining
panel.
(C) IDM Energiesysteme GmbH
Installation instructions AERO ILM
Installation
43