Transport Provisions - iDM AERO ILM 2-7 Technical Documentation Installation Instructions

Modulation air-water-heat pumps for indoor installation, with navigator 2.0 control
Hide thumbs Also See for AERO ILM 2-7:
Table of Contents

Advertisement

in the frame. Open this screw and the right side panel
can be removed.

5.16. Transport provisions

If the heat pump has to be transported by hand on
side have to be removed. There are slots in the frame
of the heat pump. 2 pipes each with a diameter of one
inch can be inserted through these. In any case these
have to be secured with four slip guards.
To ensure that the transport pipes can be pushed
through and the factory wiring is not damaged, the
wiring must be removed from the left under the elec-
trical system as shown in the picture.
(C) IDM Energiesysteme GmbH
1" pipe
After the heat pump is placed in the place of instal-
lation, the wiring is put back in the holder and the
panels can be closed again.
Installation instructions AERO ILM
slip-protection
The heat pump has to be furnished in
transporting it by hand!
Installation
45