iDM AERO ILM 2-7 Technical Documentation Installation Instructions

Modulation air-water-heat pumps for indoor installation, with navigator 2.0 control
Hide thumbs Also See for AERO ILM 2-7:
Table of Contents

Advertisement

T E C H N I C A L D O C U M E N TAT I O N
I N S TA L L AT I O N I N S T R U C T I O N S
wi t h N AV I GATO R 2.0 C o n t ro l
Modulation air-water-heat pumps
for Indoor Installation
HEAT PUMPS FROM AUSTRIA
www.idm-energie.at
A E R O I L M 2-7
A E R O I L M 4 - 1 3
A d d i t i o n a l M o d e l :
H G L
DIE ENERGIEFAMILIE

Advertisement

Table of Contents
loading

Summary of Contents for iDM AERO ILM 2-7

  • Page 1 A d d i t i o n a l M o d e l : H G L wi t h N AV I GATO R 2.0 C o n t ro l Modulation air-water-heat pumps for Indoor Installation HEAT PUMPS FROM AUSTRIA www.idm-energie.at...
  • Page 2: Table Of Contents

    1.15. Application range 1.16. Scope of delivery 1.17. Accessories 2. T ECHNICAL DATA 2.1. Dimensions of AERO ILM 2-7 and AERO ILM 4-13 2.2. Technical data 3. D IMENSIONING 3.1. Heating performance diagrams AERO ILM 2-7, according EN14511 3.2. Heating performance diagrams AERO ILM 4-13, according EN14511 3.3.
  • Page 3 8.2. Errors 9. A PPENDIX 9.1. AERO ILM 2-7 - Performance data heating - detailed 9.2. AERO ILM 2-7 - Performance data cooling - detailed 9.3. AERO ILM 4-13 - Performance data heating - detailed 9.4. AERO ILM 4-13 - Performance data cooling - detailed 9.5.
  • Page 4: General Description

    To prevent water damage, the conden- hoisting equipment. sate bin and the condensate hose have to be checked regularly for contamination. (C) IDM ENERGIESYSTEME GMBH Installation instructions AERO ILM...
  • Page 5: Ice-Covering Weather-Shield Grilles

    - the regulations of the professional associations - the pertinent laws, standards, regulations and pro- safeguarded against theft by appropriate on-site visions, e.g. DIN, EN, DVGW, VDI and VDE. measures. - Provisions of the local public utilities. (C) IDM ENERGIESYSTEME GMBH Installation instructions AERO ILM...
  • Page 6: Description

    A copper-welded stainless steel plate heat exchanger sule compressor (AERO ILM 4-13) or rolling piston is used as condenser. The machine frame consists of compressor (AERO ILM 2-7) perfectly. The housing is thus completely without a thermal bridge and thus features optimum sound in- as condenser sulation values.
  • Page 7: Technical Data

    2. Technical data Technical data 2.1. Dimensions of AERO ILM 2-7 and AERO ILM 4-13 outlet front inlet from above (C) IDM ENERGIESYSTEME GMBH Installation instructions AERO ILM...
  • Page 8: Technical Data

    Outside air outlet - maximum dB(A) Night mode dB(A) Indoor - nominal dB(A) Indoor - maximum dB(A) The sound pressure level can be calculated with the iDM-sound calculation tool Dimensions HxWxD 1850/910/830 1850/910/830 Tilt hight 2028 2028 Weight Sound data with weather shield-grilles, without air hose and without air duct. If the fan speed will be raised, the sound power level raises too.
  • Page 9 Technical data Heatpump type unit AERO ILM 2-7 AERO ILM 4-13 Maximum heatpump flow temperature m³/h 1.42 m³/h 0.42 0.77 Integrated loading pump Yonos Para 7.0 Stratos Para 25/1-9 Free residual pressure loading pump at nominal flow rate Pressure loss heating side Flow- and return connections heating side 1“...
  • Page 10: Dimensioning

    The standard outside temperature is additionally re- quired. This is determined by the geographical loca- tion and can be found on the IDM homepage and ob- tained from various institutions. Heating energy required: Heating performance diagram AERO ILM 4-13...
  • Page 11 Dimensioning Notes Notizen: (C) IDM ENERGIESYSTEME GMBH Installation instructions AERO ILM...
  • Page 12: Heating Performance Diagrams Aero Ilm 2-7, According En14511

    3. General description Dimensioning 3.1. Heating performance diagrams AERO ILM 2-7, according EN14511 NOMINAL outside temperature [° C] NOMINAL outside temperature [° C] (C) IDM ENERGIESYSTEME GMBH Installation instructions AERO ILM...
  • Page 13 Dimensioning NOMINAL outside temperature [° C] NOMINAL outside temperature [° C] (C) IDM ENERGIESYSTEME GMBH Installation instructions AERO ILM...
  • Page 14: Heating Performance Diagrams Aero Ilm 4-13, According En14511

    3. General description Dimensioning 3.2. Heating performance diagrams AERO ILM 4-13, according EN14511 NOMINAL outside temperature [° C] NOMINAL outside temperature [° C] (C) IDM ENERGIESYSTEME GMBH Installation instructions AERO ILM...
  • Page 15 Dimensioning NOMINAL outside temperature [° C] NENN outside temperature [° C] (C) IDM ENERGIESYSTEME GMBH Installation instructions AERO ILM...
  • Page 16: Limitations Of Use

    The heating of liquids other than heating water is not permitted (see heating water quality). Heat pumps are naturally subject to pressure or temperature-dependent operating limits (see diagram below). Operation outside these limits is not permitted. AERO ILM 2-7 - heating [°C] R410A [°C]...
  • Page 17 AERO ILM 4-13 - cooling [°C] R410A 10 15 20 25 30 35 40 45 50 [°C] outdoor temperature If the outside temperatures falls below or exceeds the application range , the heat pump turns (C) IDM ENERGIESYSTEME GMBH Installation instructions AERO ILM...
  • Page 18: Connections And Cable Ducts

    (only for HGL-usage in cooling mode) not used not used Heat pump return Heat pump return Main current Main current Sensor and control lines Sensor and control lines height-adjustable feet (50 mm) height-adjustable feet (50 mm) (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 19: Cable And Piping Ducts

    4.2. Hydraulic connections to the heat pump AERO ILM HGL AERO ILM (without HGL) 2 ... heat pump retur 2 ... heat pump retur (backside of HGL-condenser) (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 20: Installation

    In coastal installation, a minimum dis- tance of 5 km from the coast must be observed. If this safety distance is not observed, there could occur increased corrosion. These cases are excluded from the guarantee. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 21: Air Duct

    (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 22 (directivity correction Dc) of the relevant place of immission according the following formula: 3: Spherical spreading into 1/8 space: WAeq situations of heat pumps and the corresponding di- rectivity correction. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 23 6 dB location should be avoided sensitivity The rating level Lr shall be obtained by summing the calculated immission level and the applied correc- pressure levels accordingly. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 24: Decoupling Of Buildings

    The installation of heat pumps should be omitted around the heat pump (as shown in the illustration). 1. Betondecke 2. Trittschalldämmung 3. Estrich 4. Ausnehmung 5. Schalldämmmatte (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 25: Installation Location

    - Heat pumps must not be installed in rooms with condensate. For this purpose a drain- age must be provided. - Air intakes and outlets have to be safeguarded against theft by appropriate on-site measures. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 26: Corner Installation

    To facilitate accessibility the outlet opening on the right-hand side should be given preference! When using a light shaft this must be at least as wide as the wall opening. The depth must be at least 400 mm. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 27 (incl. outlet panel) 192502 ... Protective grating outlet air or 192532 ... Mesh grille outlet (12 mm) 192502/192532 193801 Only move the heat pump with mounted Avoid intensive pressure against the panels! wall! (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 28 The horizontal elements are principally laminated on the front side. This guarantees an optimum leak tightness! the cellular rubber on the inner side! The metal frame is thus surrounded completely with insulat- ing material and cold bridge free! (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 29 If there is any gap at the outlet or inlet opening due to ing the 4 screws which are included in the delivery contents. adjustable machine feet. The screws on the panel have to be carefully tightened manually. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 30: Installation With A Straight Air Duct

    When using a light shaft this must be at least as wide as the wall opening. The depth must be at least 400 mm. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 31 A is the length of the 1,000 mm 1,150 mm air duct plus 150 mm. 1,500 mm 1,650 mm wall insulation! The minimum width of the wall insulation must be 50 mm. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 32 Finally, the foamed area of the wall breakthrough must be covered with the panel (duct wall connection) lies in front of the wall. At the which ensures the stability of the wall socket. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 33: Installation With 90 ° Air Duct

    The air ducts can be connected to the left or to the right of the heat pump. Heating and electrical connections can also be made on both sides. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 34 The air duct can be cut to length as required, the length B is the length of the air duct plus 166 wall insulation! The minimum width of the wall insulation must be 50 mm. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 35 Thus, the blown air sinks and moves down to the lowest point. This is especially important when installing with rising or falling terrain. The air ducts are supplied including mounting material (screws, washers, nuts)! (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 36: Installation Of Flexible Air Hose - Air Outlet Sideways

    The air connections can be connected to the left or right side of the heat pump. In consequence this means that heating connections and electrical connections can be either on the left-hand side or on the right-hand side. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 37 5 m, the outlet panel, a wall mounting panel and 2 pieces hose clamps for assembly of the hose to the outlet panel and to the wall mounting panel. (min. bend radius is 600 mm) (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 38 The minimum width of the wall insulation must be 50 mm. When using a light shaft this must be at least as wide as the wall opening. The depth must be at least 400 mm. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 39 This has opening using suitable assembly material. Four bore purpose! Flexible hose: The hose can be cut to length as desired! In connect- is telescoped at the two ends. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 40: Installation Of Flexible Air Hose - Air Outlet To The Top

    (2 m, 3 m und 5 m) and can be cut to length as needed! When using a light shaft this must be at least as wide as the wall opening. The depth must be at least 400 mm. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 41 5 m, the outlet panel, a wall mounting panel and 2 pieces hose clamps for assembly of the hose to the outlet panel and to the wall mounting panel and the cover panel sideways for free cutting. (min. bend radius is 600 mm) (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 42 Increase the Wall opening according the insulation. Outlet opening to the right NOTE: Clear dimensions. Increase the Wall opening according the insulation. wall insulation! The minimum width of the wall insulation must be 50 mm. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 43 When replacing the panel, ensure that the insulation of the cover is cleanly closed at all times. If this is not the case, condensation can occur on the heat pump cover and also on the remaining panel. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 44: Modification From The Right-Hand To Left-Hand Outlet Side

    The protective sleeves for the hydraulics and cables are provided by the manufacturer on both sides. to be installed as shown in the diagram below. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 45: Transport Provisions

    After the heat pump is placed in the place of instal- lation, the wiring is put back in the holder and the panels can be closed again. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 46: Heating Connections

    Therefore avoid open heating systems or steel pipe 6.2. Safety device When working with higher temperatures by a bivalent have to be installed on sit pump operation can cause damage! operation can cause damage!. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 47: Aero Ilm With Unregulatet Direct Heating Circuit And Hygienik Without Separating Plate

    (without separating plate) Note: This is only a tentative suggestion for installing an IDM heat pump in the heating system. This suggestion replaces no professional planning of an executing companie! On part of IDM-Energiesysteme can no warrenty be taken concerning the function of the whole system! General instructions for iDM system schemes must be noted! point switch and an additional humidity sensor have to be installed.
  • Page 48: Aero Ilm With Unregulated Direct Heating Circuit And Aqa

    AERO ILM Note: This is only a tentative suggestion for installing an IDM heat pump in the heating system. This suggestion replaces no professional planning of an executing companie! On part of IDM-Energiesysteme can no warrenty be taken concerning the function of the whole system! General instructions for iDM system schemes must be noted! point switch and an additional humidity sensor have to be installed.
  • Page 49: Aero Ilm With Hygienic With Separating Plate And Mixer Circuits

    (with separating plate) (regulated) Note: This is only a tentative suggestion for installing an IDM heat pump in the heating system. This suggestion replaces no professional planning of an executing companie! On part of IDM-Energiesysteme can no warrenty be taken concerning the function of the whole system! General instructions for iDM system schemes must be noted! One heating circuit can be regulated as standard.
  • Page 50: Aero Ilm With Cooling Buffer And Hygienic With Layer Separate Plate

    (with separation plate ) Note: This is only a tentative suggestion for installing an IDM heat pump in the heating system. This suggestion replaces no professional planning of an executing companie! On part of IDM-Energiesysteme can no warrenty be taken concerning the function of the whole system! General instructions for iDM system schemes must be noted! dew point switch has to be installed to monitor the dew point.
  • Page 51: Aero Ilm With Hygienic With Layer Separate Plate And Oil-/Gas Burner

    (with separating plate) Note: This is only a tentative suggestion for installing an IDM heat pump in the heating system. This suggestion replaces no professional planning of an executing companie! On part of IDM-Energiesysteme can no warrenty be taken concerning the function of the whole system! General instructions for iDM system schemes must be noted! The start of the oil-/gas burner is done by the potential-free contact for the 2.
  • Page 52: Aero Ilm Hgl With Unregulated Direct Heating Circuit And Hygienik Without Separating Plate

    (without separating plate) Note: This is only a tentative suggestion for installing an IDM heat pump in the heating system. This suggestion replaces no professional planning of an executing companie! On part of IDM-Energiesysteme can no warrenty be taken concerning the function of the whole system! General instructions for iDM system schemes must be noted! point switch and an additional humidity sensor have to be installed.
  • Page 53: Aero Ilm Hgl With Hygienic With Separating Plate And Mixer Circuits

    (with separating plate) Note: This is only a tentative suggestion for installing an IDM heat pump in the heating system. This suggestion replaces no professional planning of an executing companie! On part of IDM-Energiesysteme can no warrenty be taken concerning the function of the whole system! General instructions for iDM system schemes must be noted! One heating circuit can be regulated as standard.
  • Page 54: Aero Ilm Hgl With Hygienik Without Separating Plate And Heating Buffer

    (without layer separation plate) Note: This is only a tentative suggestion for installing an IDM heat pump in the heating system. This suggestion replaces no professional planning of an executing companie! On part of IDM-Energiesysteme can no warrenty be taken concerning the function of the whole system! General instructions for iDM system schemes must be noted! One heating circuit can be regulated as standard.
  • Page 55: Aero Ilm Hgl With Hygenik With Separating Plate And Cockle Stove

    (with separation plate ) Note: This is only a tentative suggestion for installing an IDM heat pump in the heating system. This suggestion replaces no professional planning of an executing companie! On part of IDM-Energiesysteme can no warrenty be taken concerning the function of the whole system! General instructions for iDM system schemes must be noted! One heating circuit can be regulated as standard.
  • Page 56: Aero Ilm Hgl With Cooling And Hgl Usage In One Step

    Mount the dew point switch on a suitable location. Throttle valve M 22 M 73 Hygienik 2.0 (with separation plate) Cooling buffer AERO ILM HGL sensor and a dew point switch has to be installed to monitor the dew point. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 57: Additional Hydraulic Connection For Heat Recovery

    In cooling mode it is possible to recover the waste heat. If installing heat recovery in cooling mode, there have to be set an additional piping for the HGL- return. HGL-return for heat recovery (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 58: Power Supply

    For electrical details see the wiring diagram. Primary current electric immersion heater AERO ILM 4-13 3x400V/50Hz - 5G1,5 mm² AERO ILM 2-7 1x230V/50HZ - 3G6,0 mm² or 3x400V/50Hz - 5G1,5 mm² Primary current compressor AERO ILM 4-13 3x400V/50Hz - 5G4,0 mm²...
  • Page 59: Lectrical Connection

    The sensor cables which have to be installed on site, have to be feed through the grommet on the right side. (C) IDM Energiesysteme GmbH Installation instruction AERO ILM...
  • Page 60: Connection Diagram For The Electric Components

    113 114 115 116 117 118 119 120 121 122 123 extension modul external / Cascade participants SD - Card EEV2 X4 EEV1 X2 RS232 X36 LAN X33 132 131 130 - SH Step motor module EIB/KNX SD- Card Touchdisplay (C) IDM Energiesysteme GmbH Installation instruction AERO ILM...
  • Page 61: Configuration Of Sensors

    (all other sensors are optional depending on the contact thermostat is required. The safety shutdown of the charge pump operates in this case directly via the heat pump. The sensor lines must be laid separately (C) IDM Energiesysteme GmbH Installation instruction AERO ILM...
  • Page 62: Connecting External Specifications 0-10V

    Together with the lines of the energy supply companies, of transmission equipment and other communication facilities §electromagnetic pollution” that is invisible for us is created. (C) IDM Energiesysteme GmbH Installation instruction AERO ILM...
  • Page 63: Start-Up

    An annual inspection and maintenance of the system 8.1. Information regarding the start-up by customer service is recommended, in particular Before starting up the IDM heat pump ensure water with regard to protecting the guarantee claims. tightness on the heating side, rinse the heat pump...
  • Page 64: Appendix

    9. 9. 9. Start-up 9. General description Genera Genera 9. Appendix 9.1. AERO ILM 2-7 - Performance data heating - detailed outdoor temperature [°C] W 35 °C heat capacity [kW] 10,65 10,52 10,38 9,90 8,91 6,56 6,19 5,61 4,78 4,30...
  • Page 65: Aero Ilm 2-7 - Performance Data Cooling - Detailed

    Appendix 9.2. AERO ILM 2-7 - Performance data cooling - detailed outdoor temperature [°C] cooling capacity [kW] 9,37 power consumption [kW] 3,79 cooling capacity [kW] 4,76 5,09 5,62 5,75 power consumption [kW] 1,29 1,13 1,01 0,94 3,70 4,50 5,57 6,09...
  • Page 66: Aero Ilm 4-13 - Performance Data Heating - Detailed

    2,68 2,70 3,25 2,99 2,84 2,71 2,54 2,21 heat capacity [kW] 4,80 4,74 4,19 3,94 3,57 3,15 power consumption [kW] 1,29 1,26 1,28 1,27 1,26 1,28 3,73 3,76 3,28 3,11 2,83 2,47 (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 67: Aero Ilm 4-13 - Performance Data Cooling - Detailed

    3) To ensure the minimum cooling output rate of distribution system, appropriate zones have to remain open A35/W18. Minimum cooling consumption 5.1 kW To ensure a large cooling demand, the cooling limit has to be set as high as possible. (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 68: Aero Ilm 2-7 - Product Data Sheet

    9. General description Appendix 9.5. AERO ILM 2-7 - Product data sheet IDM-Energiesysteme GmbH A-9971 Matrei i.O., Seblas 16 – 18, Telefon +43 (0)4875 6172-0 Firmenbuch.Nr. 44919h, LG Innsbruck, Firmensitz: 9971 Matrei i.O., UID-Nr.: ATU 433 604 02 (C) IDM Energiesysteme GmbH...
  • Page 69: Aero Ilm 4-13 - Product Data Sheet

    9.6. AERO ILM 4-13 - Product data sheet IDM-Energiesysteme GmbH A-9971 Matrei i.O., Seblas 16 – 18, Telefon +43 (0)4875 6172-0 Firmenbuch.Nr. 44919h, LG Innsbruck, Firmensitz: 9971 Matrei i.O., UID-Nr.: ATU 433 604 02 (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 70 9. General description Appendix Notes Notizen: (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 71: Declaration Of Conformity

    Appendix 9.7. Declaration of conformity (C) IDM Energiesysteme GmbH Installation instructions AERO ILM...
  • Page 72 Akademy: PRACTICAL KNOWLEDGE FOR SALES AND TECHNOLOGY The comprehensive range of seminars for specialists at the IDM POWER FAMILY is available to you any time on our websitE. We look forward to receiving your registration. YOUR iDM PARTNER: DIE ENERGIEFAMILIE...