Installation With 90 ° Air Duct - iDM AERO ILM 2-7 Technical Documentation Installation Instructions

Modulation air-water-heat pumps for indoor installation, with navigator 2.0 control
Hide thumbs Also See for AERO ILM 2-7:
Table of Contents

Advertisement

5.11. Installation with 90 ° air duct
This variant is required if the intake and exhaust can not be made corner-wise as a result of structural reasons.
The air inlet and air outlet are thus parallel to each other and there is a risk that a short circuit between air
inlet and air outlet is created. A corresponding physical separation between inlet and outlet air should prevent
a short circuit.
192521
192521 ... Wall connection intake for airtight changeover
192501 ... Weather-shield grilles inlet
192531 ... Mesh grilles inlet (12 mm)
193805 ... outlet panels for air duct
192551 ... air duct outlet isolated 1.0 m
192552 ... air duct outlet isolated 1.5 m
192554 ... air duct 90° curve, isolated
193809 ... cover for wall breakthrough for air duct
192555 ... air duct wall connection, isolated
192558 ... Weather-shield grilles outlet via air duct
192559 ... Mesh grilles outlet via air air duct (12 mm)
The air ducts can be connected to the left or to the right of the heat pump. Heating and electrical
connections can also be made on both sides.
The air ducts can be connected to the left or to the right of the heat pump. Heating and electrical
connections can also be made on both sides.
(C) IDM Energiesysteme GmbH
192501/192531
193805
192551/192552
Installation instructions AERO ILM
192555
192558/192559
193809
192554
Installation