9.4. AERO ILM 4-13 - Performance data cooling - detailed
W18
cooling capacity [kW]
power consumption [kW]
EER
cooling capacity [kW]
power consumption [kW]
EER
cooling capacity [kW]
power consumption [kW]
EER
W12
cooling capacity [kW]
power consumption [kW]
EER
cooling capacity [kW]
power consumption [kW]
EER
cooling capacity [kW]
power consumption [kW]
EER
W7
cooling capacity [kW]
power consumption [kW]
EER
cooling capacity [kW]
power consumption [kW]
EER
cooling capacity [kW]
power consumption [kW]
EER
To guarantee a correct cooling mode, when working with unregulated direct-heating circles (without cooling
1) To ensure the minimum volume of heating site, appropriate zones have to remain open all the time.
Minimum volume 144 lt.
3) To ensure the minimum cooling output rate of distribution system, appropriate zones have to remain open
A35/W18. Minimum cooling consumption 5.1 kW
To ensure a large cooling demand, the cooling limit has to be set as high as possible.
(C) IDM Energiesysteme GmbH
outdoor temperature [°C]
40
35
30
12,61
13,94
15,12
4,55
4,07
3,71
2,77
3,43
4,07
8,78
9,48
10,02
2,64
2,31
2,12
3,33
4,10
4,73
6,56
6,94
7,16
2,39
2,10
1,90
2,74
3,30
3,77
outdoor temperature [°C]
40
35
30
10,94
12,27
13,45
4,87
4,36
3,97
2,25
2,82
3,38
7,04
7,74
8,28
2,57
2,20
2,00
2,74
3,51
4,14
4,91
5,29
5,52
2,14
1,85
1,65
2,29
2,86
3,35
outdoor temperature [°C]
40
35
30
8,59
9,79
10,85
4,15
3,71
3,39
2,07
2,64
3,20
6,01
6,76
7,34
2,66
2,23
2,01
2,25
3,03
3,65
4,12
4,56
4,83
1,74
1,49
1,33
2,36
3,06
3,64
Installation instructions AERO ILM
25
20
15
16,14
-
-
3,45
-
-
4,69
-
-
10,38
-
-
1,99
-
-
5,21
-
-
7,22
-
-
1,74
-
-
4,15
-
-
25
20
15
14,48
15,34
-
3,63
3,46
-
3,99
4,43
-
8,65
8,85
-
1,86
1,78
-
4,64
4,98
-
5,58
5,49
-
1,52
1,40
-
3,68
3,93
-
25
20
15
11,77
12,55
13,18
3,02
2,86
2,80
3,89
4,39
4,70
7,74
7,95
8,00
1,86
1,77
1,70
4,15
4,49
4,69
4,90
4,79
4,50
1,20
1,09
0,98
4,09
4,41
4,57