Installation With A Straight Air Duct - iDM AERO ILM 2-7 Technical Documentation Installation Instructions

Modulation air-water-heat pumps for indoor installation, with navigator 2.0 control
Hide thumbs Also See for AERO ILM 2-7:
Table of Contents

Advertisement

5. General description
Installation

5.10. Installation with a straight air duct

This variant is similar to the corner installation and can be used if the direct corner installation without channels
from on-site conditions can not be implemented.
192521 ... Wall connection intake for airtight changeover
192501 ... Weather-shield grilles inlet
192531 ... Mesh grilles inlet (12 mm)
193805 ... outlet panels for air duct
192551 ... air duct outlet isolated 1.0 m
192552 ... air duct outlet isolated 1.5 m
193809 ... cover for wall breakthrough for air duct
192555 ... air duct wall connection, isolated
192558 ... Weather-shield grilles outlet via air duct
192559 ... Mesh grilles outlet via air air duct (12 mm)
The air ducts can be connected to the left or to the right side of the heat pump. In consequence
this means that heating connections and electrical connections can be either on the left-hand side
or on the right-hand side.
When using a light shaft this must be at least as wide as the wall opening. The depth must be at
least 400 mm.
30
192521
192501/192531
193805
Installation instructions AERO ILM
193809
192551/192552
(C) IDM Energiesysteme GmbH
192555
192558/192559