Setting Switches

Back
2-5

Setting Switches

2-5-1 Node Number Switches

Switch settings determine how the SYSMAC LINK Units will work together in
a Network. Be sure to turn the power off to the PC before setting the
switches. Errors in switch settings, which may not always be detected by the
System, can cause faulty data communications. Set and check all switch set-
tings carefully.
Turn off the power to the PC before setting the node number switches. Node
number switches determine the node number. The left switch sets the tens
digit; the right switch sets the ones digit. The node number must be between
01 and 62. Each SYSMAC LINK Unit in a Network must have a unique node
number.
Use a small flat-blade screwdriver to set node number switches, being care-
ful not to damage them.
Note Units in the same network must have unique node numbers.
Section 2-5
4
3
DIP switch 2
2
1
15