Memory Area Designations

6-3-3 CV-mode Response Codes

6-4

Memory Area Designations

Memory area
IR and SR
Bit status
Word contents
Link Relay
Bit status
Word contents
Holding Relay
Bit status
Word contents
Auxiliary Relay
Bit status
Word contents
Timer/Counter
Completion Flag status
PV
DM Area
Word contents
EM Area
Word contents
88
A 2-byte response code is returned with all responses. The first byte contains the
main code indicating the general category of the response, and the second byte
contains the sub-code giving more specific information. The table below shows
the main codes. Refer to 8-1 Troubleshooting for details on sub-codes.
Main code
00
Normal completion
01
Source node error
02
Destination node error
03
Controller error
04
Not executable
05
Routing error
10
Command format error
11
Parameter error
20
Read not possible
21
Write not possible
22
Not executable in current PC mode
23
No Unit
24
Start/stop not possible
25
Unit error
26
Command error
30
Access right error
The following table gives the addresses that can be used when reading or writing
PC data. The Data area address column gives the data area addresses normally
used in the PC program. The Address used in communications column are the
PC memory addresses used in CV-mode commands and responses. These
addresses are combined with the memory area codes to specify PC memory
locations. These addresses are not the same as the actual memory addresses
of the data.
The Bytes/item column specifies the smallest increment of data that can be read
or written for that area. The increment will be either words (2 bytes) or bytes (1
byte).
Data
Data area address
00000 to 25515
000 to 255
LR 0000 to LR 6315
LR 00 to LR 63
HR 0000 to HR 9915
HR 00 to HR 99
AR 0000 to AR 2715
AR 00 to AR 27
TC 000 to TC 511
TC 000 to TC 511
DM 0000 to DM 9999
EM 0000 to EM 6143
Note
1. The actual size of memory areas depends on the PC model being used.
Refer to the PC Operation Manual for details on memory area ranges.
Description
Address used in
communications
area code
000000 to 00FF0F
00
000000 to 00FF00
80
03E800 to 04270F
00
03E800 to 042700
80
042800 to 048B0F
00
042800 to 048B00
80
048C00 to 04A70F
00
048C00 to 04A700
80
000000 to 01FF00
01
000000 to 01FF00
81
000000 to 270F00
82
000000 to 17FF00
90 to 98
Section 6-4
Memory
Bytes/
item
1
2
1
2
1
2
1
2
1
2
2
2