7. Appendix: Error/Warning Indications
Display indication
Cannot Use SxS(A)*
Unsupported File System
Media Error
SxS(A)* Needs to be Restored
SxS(A)* Error
Recording Stopped
Playback Stopped
Input AES/EBU is Invalid Emphasis
Input AES/EBU is not Pro Use
Fan Stopped
AXS Recorder Fan Stopped
Unsupported FPS
Change AXS(A) to AXS S48 Memory
Abnormal Lens Communication
Please Check "Lens IF" Setting
Please Execute APR
XXXX License Y days Remaining
(XXXX: Type of license, Y: Number of days remaining)
Lens I/F Error
* "SxS(B)" is displayed for the SxS memory card in slot B, "AXS(A)" is displayed for the AXS memory card in slot A of the AXS-R7,
and "AXS(B)" is displayed for the AXS memory card in slot B of the AXS-R7.
Cause and Solution
A card using a different file system or an unformatted
card was inserted.
The card cannot be used in the unit, and must be
replaced or formatted using the unit.
An error occurred with the memory card. The card
requires restoration.
Restore the card.
Recording or playback stopped because an error
occurred on the memory card.
If the problem persists, replace the memory card.
Emphasis signal that is not compatible with the AES/
EBU input was input.
The unit is compatible with 50u-15u Emphasis only.
A signal other than Professional Use was input to the
AES/EBU input.
The unit is compatible with Professional Use only.
The fan in the unit has stopped.
Avoid use under high temperature conditions. Turn
the unit off and contact a Sony service representative.
The fan in the AXS-R7 that is connected to the unit
has stopped.
Avoid use under high temperature conditions.
Remove the AXS-R7 from the unit and contact a Sony
service representative.
Unsupported AXS memory was detected.
Recording cannot be performed. Change the
recording format for the AXS memory card, or change
the card to an AXS-A512S48 or AXS-A1TS48.
The type of the connected lens does not match the
unit's setting.
Check the Technical > Lens Configuration > PL-Mt
Interface Position setting in the full menu.
The auto adjusting of the image sensor (APR) has not
been executed for a certain period.
Execute APR by pressing the MENU dial.
There are 2 days remaining before the license for the
software option will expire.
A fault was detected in the lens I/F communication
when an E-mount lens is attached.
Check the connection to the E-mount lens.