8.4.3 Retentive Status Function

Retentive Status Function is for temporarily saving transmission information in this product. Temporarily saved
information is transmitted to WDR, in order, from oldest to newest. The maximum amount of information that can be
saved temporarily is as follows.
●When Input Information Transmission Format is [WDT-LR Format]
Signal Tower Control Line Information
External Input Line Information
RS-232C Communication Data
(60 byte transmission)
●When Input Information Transmission Format is [WDT-PRO Format]
Signal Tower Control Line and External
Input Line Information
RS-232C Communication Data
(60 byte transmission)
●When the maximum size of information is exceeded, information is deleted beginning with the oldest.

8.4.4 Receive Information Function

Function for the WDT-PRO to wirelessly receive from the host remote control commands for the LED and
buzzer unit, or data to transmit to external equipment connected to WDB-D80S. The following is an illustration of
transmissions to external equipment.
External
Equipment
32
32
32
32
Transmission Data
RS-232C Cable
5
5
NOTICE
Transmission Data