8.2.5 Simple Counter Function

・Count up the number of pulse inputs (increment 1 at a time) on a single Signal Tower control line and store the
accumulated value (counter value) on WDT-PRO.
・At startup the counter value is 0 (initial value).
・The value range of the counter is 0 to 4,294,967,295.
・Pulse inputs are determined using the following criteria.
Input
O N
OFF
100 ms or longer
Result
Evaluating
●When counting up exceeds the upper limit, the counter value returns to 1.
●When the power is shut down, the counter value is cleared to 0.
●In WDS-WIN01, you can reset the counter value to 0 (initial value).
●Regardless of changes in states, the Signal Tower information in the counter settings is not transmitted. The Signal Tower
information is treated as if the light is off and buzzer is off.
* Use WDS-WIN01 to select the Signal Tower control line for a simple counter.
* The default setting for the simple counter is [Do not setup].
100 ms or longer
Count up