Wireless Data Communication System - WD PRO Series Instruction Manual
7.3.3 Checking the WDB-D80S Status Lamp
The product's status lamp is located where you detach the direct mount bracket from the WDB-D80S.
●Status Lamp States
State*
Green light on
Normal
Status
Red light on
Flashing green
Alternating
Red→Green→Red→Green
Error
Status
Green light on
* Operation modes shown by the status lamp are [Normal Status] and [Error Status].
* When the status lamp lights indicate an error status, refer to "9.1 Troubleshooting( P.58)".
LED1
Status Lamp
LED1
Red→Green→Red→Green
Light off
Light off
LED2
LED2
Light off
Green light on
-
Alternating
Green light on
Flashing red
Flashing red
41
Status
Operating in normal mode.
Operating in initialization mode.
WDB-D80S DIP switches set up incorrectly.
Error has occurred in WDB-D80S.
Error has occurred in WDT-PRO.
7. Operation