Connecting the ODU to the IDU

The connectors are 3 pin in line female, with polarities (left to right) minus,
ground, plus. To avoid damage to the IDU, always use an AC/DC adapter
supplied by RADWIN.
Ensure that the IDUs at both sites are powered up.
The IDU-E/R models have a two pin power connector and an AC/DC
adapter supplied by RADWIN.
Connecting the ODU to the IDU
The ODU-IDU cable conducts all the user traffic between the IDU and the
ODU, and also provides power to the ODU. The maximum length of the
ODU-IDU cable is 100m (328ft) in accordance with 10/100BaseT standards.
The ODU-IDU cable is supplied pre-assembled with RJ-45 connectors, at the
length specified when ordering, or as a cable drum with spare connectors. If
the ODU-IDU cable was not ordered, use an outdoor class, CAT-5e 24AWG
shielded cable. See
To connect the ODU to the IDU, route the cable from the ODU to the IDU,
secure the cable along its path and connect the cable to the ODU RJ-45
connector on the IDU (see item B in

Installing a Link using PoE Devices

The PoE device is a very simple unit having a power input connector and
two Ethernet ports. It is AC powered, and has a power LED.
To prepare a link using PoE devices:
1. To connect the ODU to the PoE device, route the cable from the ODU to
the PoE device, secure the cable along its path and connect the cable to
the LAN-OUT RJ-45 connector on the PoE device.
2. Connect it to AC power.
3. Repeat steps 1 to 2 for the second link.
4. If you are using a BDU, you should refer to the RADWIN Base Distribution
Unit User Manual.

Connecting User Equipment

To connect user equipment to an IDU:
1. Connect user switch/router or any other compatible device to the IDU
panel RJ-45 ports designated LAN. (For an IDU-C, see item C in
Figure 3-13
2. Connect user E1/T1 traffic to the IDU panel RJ-45 ports designated
TRUNKS. (For an IDU-C, see labeled item L in
3. IDU-C only: To use the SFP Port (labeled item D in
insert an SFP plug-in module into the port and connect the user switch/
router or any other compatible device to the SFP plug-in module.
WinLink™ 1000 User Manual
Appendix K
for Wiring Specifications.
Figure 3-13
above.)
Release 1.9
Chapter 3
above).
Figure 3-13
above.)
Figure 3-13
above),
3-14