HSS Link Configuration
To configure the Operational States of the Hub Site unit
1. Click the Enabled check box
2. Click the Configure button
The Hub Site Configuration dialog box with the current status of the
ODUs is displayed.
3. Select the type of unit configuration from the drop-down list.
4. Select the appropriate RFP radio button. Some RFP options may be dis-
abled depending on the BW previously selected.
Take care to avoid incorrect configuration of bandwidth, RFP or to
set multiple Hub Sync Masters, as system interference can occur.
RADWIN Manager gives error messages and tool tips if the system
Note
is configured with mismatches.
Figure H-7: Hub Site Configuration dialog box
WinLink™ 1000 User Manual
Hub Sync Client - Continue Transmission (HSC-CT)
Independent Unit
Synchronization:
N/A- for Master or Independent Units
Synchronized - for Hub Site Clients
Not Synchronized - for Hub Site Clients
External Pulses: The status of the pulses running through the HSS
cable. The Master generates such pulses. The severity of each of
these states is indicated by by green, yellow or red text color.
Release 1.9
Appendix H
H-7