RADWIN Manager Community Strings
To change a Community string:
1. From the Configuration dialog box, choose the Security tab.
2. Type the current read-write Community (default is
3. Choose the communities to be changed by clicking the check box.
4. Type the new Community string and re-type to confirm.
5. Click OK to save.
Figure 8-8: Changing the Community String

Forgotten Community string

If the read-write Community string is unknown, an alternative Community
key can be used. The alternative Community key is unique per ODU and can
be used only to change the Community strings. The alternative Community
key is supplied with the product, and should be kept in a safe place.
If both the read-write Community and the alternative Community key are
unavailable, then an alternative Community key can be obtained from RAD-
WIN Customer Support using the ODU serial number or MAC address. The
serial number is located on the product label. The serial number and the
MAC address are displayed in the Site Configuration inventory tab.
When you have the alternative Community key, click the Forgot Commu-
nity button and enter the Alternative Community key
change the read-write Community string.
WinLink™ 1000 User Manual
For Read-Write Community, use
For Read-Only Community, use
For Trap Community, use
Release 1.9
netman
.
public
.
public
netman
(Figure
Chapter 8
).
8-9). Then
8-9