Figure H-1 Interference Caused By Collocated Units; Figure H-2 Collocated Units Using; Figure H-3 Collocated Units Using - Radwin WinLink 1000 Series User Manual

Broadband wireless transmission
Table of Contents

Advertisement

What is Hub Site Synchronization?
Figure H-1: Interference caused by collocated units
Figure H-2: Collocated units using Hub Site Synchronization (1)
Figure H-3: Collocated units using Hub Site Synchronization (2)
The units are connected to each other with HSS cables and HSS Distribution
Units.
One of the radios in the site is defined as HSS Master and generates syn-
chronization pulses.
The other collocated radios in the site - the HSS Clients, are connected to
the HSS Master and synchronize their transmission to the pulses. An HSS
Client can be configured to work in one of two modes:
WinLink™ 1000 User Manual
Release 1.9
Appendix H
H-2