Replacing an ODU
Replacing an ODU
Prior to any action ensure that both ODUs have the same software version.
You can see this on the inventory panels for each site.
For Site A, click Site A | Inventory and note the ODU software version.
Repeat this for Site B using Site B | Inventory.
If either ODU has an old software version, perform a software upgrade. It is
important to configure the new ODU exactly the same as the old ODU to
avoid configuration mismatches, which will disrupt the link.
An ODU may be reconfigured in several ways.
• Use the backup configuration
• Manual configuration
Restoring Factory Setup
To restore factory setup:
• Use Site Configuration A or B, and then Operations | Restore
Defaults. Always restore the over-the-air site (B) first.
Online Help
Online help can be accessed from the Help menu on the main window of
the RADWIN Manager.
Customer Support
Customer support for this product can be obtained from the local VAR, Inte-
grator or distributor from whom it was purchased.
For further information, please contact the RADWIN distributor nearest to
you or one of RADWIN's offices worldwide.
WinLink™ 1000 User Manual
If a backup of the configuration is available, restore that
configuration using Site A| Restore.
The new ODU can be configured manually according to the link
configuration. Remember to use the same settings for Link ID,
channels, link password, IP addresses, and names.
Release 1.9
Chapter 9
9-20