External Alarms Specification
Each of the three products, IDU-E-AL, IDU-C and PoE-8 have a dry contact
alarm relay through a standard DB9 or DB25 pin female connector. There
are two alarm types – input and output.
Input alarms
The input alarms are raised by events from external equipment, such as
a fire warning, door open or air conditioner failure. They are user
defined.
Output alarms
Output alarms are generated through dry contact relays to indicate vari-
ous system events such as sync loss or disconnection. An alarm is raised
if at least one of the conditions in one of the tables below, is met.
IDU-C Alarms
Table R-1: IDU-C - Output Alarms Description
Alarm
Description
Output 1
Air interface Alarm
Output 2
Equipment Alarm
Output 3
Service Alarm at Site B
Output 4
Power Failure at Site B
WinLink™ 1000 User Manual
External Alarms
Specification
Alarm On Conditions
•
Link is down
•
Link in installation mode
•
Link authentication problem
•
Built in Test (BIT) error
•
No connection to the ODU
N/A
Link Loss due to Power Failure at Site B
Release 1.9
Appendix R
Alarm Off Condition
Link is up or equipment alarm is ON
Both ODU and IDU are in operational
state
Permanently off
Link is up or down without power failure
indication within the last two seconds
R-1