CHAPTER 2: INSTALLATION INSTRUCTIONS

Each iMcV-Giga-FiberLinX-III module requires one slot in an iMediaChassis,
MediaChassis or IE-MediaChassis. To install the module in a chassis, remove
the blank faceplates covering the slots where the module is to be installed. Then
slide the module into the chassis card guides until the module is seated securely
in the connector. Secure the module to the chassis by tightening the captive
screw.
The iMcV-Giga-FiberLinX-III module includes on-board SNMP logic. A chassis
other than an iMediaChassis series cannot manage an iMcV-Giga-FiberLinX-III,
so the iMcV-Giga-FiberLinX-III must be managed independently.
When installed in an iMediaChassis, the iMcV-Giga-FiberLinX-III module can be
managed from the chassis by using the Unified Management Agent (UMA).
iMcV-Giga-FiberLinX-III modules not managed by UMA must have an IP address
assigned to them after installation before they can be managed. Refer to
Assigning IP Information for more information.
DIP SW ITCH SELECTABLE MODE CONFIGURATION
Before installing the module in a chassis, there are two features that must be
selected using the DIP switches. These selections are:
Enable or disable management on each port
(DIP switches 1, 2, and 3)
Configure module as standalone, host, or remote
(DIP switches 7 and 8)
DIP SW ITCH SETTINGS
Before installing the iMcV-Giga-FiberLinX-III, use the DIP switches to set the
hardware configurable features. The DIP switches are located on Bay SW1
on the iMcV-Giga-FiberLinX-III card. Refer to the diagram and table for
switch settings and available features.
iMcV-Giga-FiberLinX-III
DIP switch (SFP model).