6 Programming the control
6.10 Linear motors (1FN1 and 1FN3 motors)
Table 6-28
Assignments of temperature sensor coupling lead
Signal
Temperature sensor +
Temperature sensor –
Temperature switch/PTC
Temperature switch/PTC
6-146
Note
The outer and inner shielding of the signal lines in the power cable and the
shielding for the temperature sensor coupling lead MUST be laid flat on the
shielding connecting plate.
Failure to connect the shield correctly can result in high touch voltages, mal-
functions and sporadic errors or irreparable damage to the closed-loop control
module.
Power cable
Black core
Brown + black core
White core
Orange + red core
–
Yellow core
Red core
–
SINUMERIK 840D/810D Start-Up Guide (IADC) – 03/2006 Edition
Temperature sensor coupling lead
(dongle)
© Siemens AG 2006 All Rights Reserved
03/2006
–X411
on drive
Pin 13
Pin 25
–
–