Handling Machine And Setting Data - Siemens SINUMERIK 840D Simodrive 611 digital Startup Manual

Table of Contents

Advertisement

6 Programming the control
6.2

Handling machine and setting data

6.2
Handling machine and setting data
Number and
identifier
Active
Protection levels
Unit
Default value
6-52
MD and SD are addressed by number or by name (identifier). The number and
name are displayed on the HMI user interface. The following must also be
noted:
S
Active
S
Protection level
S
Unit
S
Default value
S
Value
The levels at which a data item takes effect are listed below in order of priority.
A change to the data takes effect after:
S
POWER ON (po)
NCK-RESET
S
NEW_CONF (cf)
– "Activate MD" soft key on the HMI
– "RESET" button on the MSTT
– Changes in program mode at the start and end of
records possible
S
RESET (re)
– at the end of program M2/M30, or
– "RESET" button on the MSTT
S
IMMEDIATELY (so)
after entering the value
Protection levels are identified by numbers and are used to enable data areas.
A more detailed explanation can be found in the next section: Protection level
concept.
The unit refers to the default setting for the machine data:
S
MD_$MN_10220_SCALING_USER_DEF_MASK (activates the scaling
factors)
S
MD_$MN_10230_SCALING_FACTORS_USER_DEF (scaling factors for
the physical variables)
S
MD_$MN_10240_SCALING_SYSTEM IS METRIC=1 (basic system is
metric)
If the MD is not based on any physical unit, then the field contains a "–".
This value is used to set the machine or setting data to its default.
Note
On the HMI, input is limited to 10 digits plus decimal point and sign.
SINUMERIK 840D/810D Start-Up Guide (IADC) – 03/2006 Edition