Siemens SINUMERIK 840D Simodrive 611 digital Startup Manual page 200

Table of Contents

Advertisement

10 Drive Optimization
10.7 Trace function
Physical address
soft key
Segment address
input box
Offset address input
box
Mask input box
Threshold input box
10-200
The entries are made in the servo trace function basic screen.
S
The "Physical address" signal type must be selected in the desired trace.
S
The cursor in the desired trace must be positioned in the associated signal
selection box (on Physical address).
The physical address dialog box is overlaid when you activate the Physical
address soft key.
Note
This function is only required in special cases when the information from the
usual signals (see "Signal selection" list field) is insufficient. Please contact the
SIMODRIVE hotline to discuss how to proceed.
Fig. 10-10 Input screen for setting the physical address parameters.
All parameters settings are entered in hexadecimal format.
Direct input of the segment address of the signal to be logged.
Direct input of the offset address of the signal to be logged.
If you want to display certain bits only, select them in this dialog box.
In the "Threshold" input box, you can only set the trigger threshold for the physi-
cal address of trace 1. If you exit the input box by activating the OK soft key, this
hexadecimal value is entered in the "Threshold" field of the servo trace basic
display.