6.12 System settings for power-up, RESET and starting part programs

6.12
System settings for power-up, RESET and starting part
programs
Concept
The response of the control changes after the following actions:
S
S
S
The following machine data settings affect the above actions:
MD 20110: RESET_MODE_MASK (define the basic control settings
MD 20112: START_MODE_MASK (define the basic control settings
Table 6-30
Power-up (POWER-ON),
RESET/end of part program
Start of part program
Procedure
Select the required system response.
S
Fig. 6-46
© Siemens AG 2006 All Rights Reserved
SINUMERIK 840D/810D Start-Up Guide (IADC) – 03/2006 Edition
Power-up (POWER-ON),
Reset/end of part program and
Start of part program
Changing system settings with MD
Status
RESET_MODE_MASK
RESET_MODE_MASK
START_MODE_MASK and
RESET_MODE_MASK
after power-up (POWER-ON)
MD 20110: RESET_MODE_MASK, Bit 0 =
Power-up
(POWER-ON)
MD 20110
Bit 0=0
RESET_MODE_MASK
Bit 0
Bit 0=1
– G codes as per MD 20150: GCODE_RESET_VALUES
– Tool length correction active as per MD 20120: TOOL_RESET_
VALUE, MD 20121: TOOL_PRESEL_RESET_V ALUE and
MD 20130: CUTTING_EDGE_RESET_VALUE
– Transformation active as per MD 20140: TRAFO_RESET_VALUE
– No coupled units active
– No tangential adjustment active
– Non-configured synchronous spindle coupling is switched off
System settings after power-up
6 Programming the control
after power-up and reset) and
after start of part program)
can be changed by MD
0 or 1
– G codes as per MD 20150: GCODE_
RESET_VALUES
– Tool length correction not active
– Transformation not active
– No coupled units active
– No tangential adjustment active
– Non-configured synchronous spindle
coupling is switched off