Siemens SINUMERIK 840D Simodrive 611 digital Startup Manual page 153

Table of Contents

Advertisement

03/2006
Determining the
After connecting the oscilloscope, first move the drive over the zero marker that
commutation
the drive is synchronized.
angle
Fig. 6-45
Definition of channels (Ch1 ... Ch4):
S
S
S
S
Note
If you select the "Scaled, electrical rotor position" measured signal, the SHIFT
factor should be changed from 7 to 8 and the offset value from –1.25V to –2.5V.
For a synchronized drive, the difference between the EMF/phase U and the
electrical rotor position should not exceed $10_.
If the difference is greater, the position of the zero marker must be moved in the
software in MD 1016 "COMMUTATION_ANGLE_OFFSET".
© Siemens AG 2006 All Rights Reserved
SINUMERIK 840D/810D Start-Up Guide (IADC) – 03/2006 Edition
6.10 Linear motors (1FN1 and 1FN3 motors)
Ch1/Phase U
Ch4
Determining the commutation angle offset by measuring the EMF and
normalized electrical rotor position via DAC in a positive drive direction
Ch1: EMF Phase U to star point
Ch2: EMF Phase V to star point
Ch3: EMF Phase W to star point
Ch4: Scaled electrical rotor position via DAU measured signal
6 Programming the control
Ch2/Phase V
Ch3/Phase W
6
6-153