4000 Series GSM Audio Intercom with Proximity
Programming the GSM Intercom
readers or keypads) for the different devices at various times. In the case of dial to open (DTO) numbers the timebands feature
enables and disables when the dial to open numbers can be used.
Like the TBA timeband feature the start and end times for the timebands used in the programming command must use 24hr clock
notation. For example, if timeband 0 is set from 8:45am to 7:30pm then the user(s) will only be able to use their fobs/cards, access
code(s) and dial to open numbers between the hours of 08:45 in the morning until 19:30 in the evening. Also the timebands can be
set for a specific day or days of the week to be active for by adding the day or days to the end of the programming command, see
table on page 46 for the codes used for the days required.
When including the day or days in the command they must be separated using a comma , between the codes required, also refer
to the following examples. Use the following text messages to store, query and delete the timebands.
1111ATBn"HHMMHHMM",days
1111ATBn"HHMMHHMM",days?
1111ATBn?
1111ATBn""
1111ATBn""?
Example 1: To set timeband 0 to allow for proximity fobs/cards, access codes and dial to open numbers to be active between
8:00am in the morning up until 2:00pm in the afternoon and for weekends only, the following text can be sent to the
GSM PRO intercom, remembering to use 24hr clock notation:
The GSM PRO intercom will reply with the following text:
Example 2: To set timeband 1 to allow for proximity fobs/cards, access codes and dial to open numbers to be active between
2:00pm in the afternoon until 3:00pm in the afternoon and for Mondays, Wednesdays and Fridays only, the following
text can be sent to the GSM PRO intercom, remembering to use 24hr clock notation:
Note that commas , are used where appropriate to separate the days required for the timeband. The GSM PRO
intercom will reply with the following text:
Note that in both examples shown the confirmation text message from the GSM PRO will include the day or days of
the week shown after the timeband period.
IMPORTANT NOTE: When using the Art.4903 keypad the ATB timebands feature only applies to the additional 400 (000 - 399)
access codes and 32 (400 - 431) temporary codes. Any codes programmed for relays 1 and 2 directly via the keypad will work as
normal and are not affected by the timebands. It should also be noted that the ATB timebands feature cannot be used alone it
must also be used in conjunction with the access levels feature ACC described on the following page.
4000 Series GSM Audio Intercom - Technical Manual
Store the time period for timeband n, where n = timeband no. (0 - 9) using this format:
the first HHMM is the start time for fobs/cards and access codes to be active (i.e. 0845
for 8:45am in the morning) and the second HHMM is the end time when fobs/cards and
access codes will stop being active (i.e. 1930 for 7:30pm at night) and where days = Mo, Tu,
We, Th, Fri, Sa, Su, AD, WD, WE.
As above but also send a confirmation text back to the sender with the stored setting.
Query timeband n setting, where n = timeband no. (0 - 9) A text message will be sent to
the sender with the stored timeband no., time period and days active for.
Delete timeband n, where n = timeband no. (0 - 9).
Delete and confirm deletion of the timeband.
1111ATB0"08001400",WE?
ATB0 = 08001400,Su,Sa
OK VIDEX GSM
1111ATB1"14001500",Mo,We,Fr?
ATB1 = 14001500,Mo,We,Fr
OK VIDEX GSM