Videx 4000 Series Technical Manual page 15

Gsm audio intercom kit
Hide thumbs Also See for 4000 Series:
Table of Contents

Advertisement

4000 Series GSM Audio Intercom with Proximity
Art. 4903 Technical Information
PROGRAMMING AS A STANDALONE KEYPAD
When using the Art.4903 as a standalone keypad the programming is the same as the programming of an Art.4800M keypad
(refer to programming guide and flowchart below). All programming is carried out using the keypad. The programming menu is
protected by an ENGINEER'S CODE, the factory default of which is six times 1 ("111111"). This code can be changed to any 4 to 8
digit ENGINEER'S CODE during the programming and is used to gain entry to the programming menu only.
Each relay (RLY1 and RLY2) can be programmed with a 4 - 8 digit access code (one code per relay) and will activate the respective
relay for the programmed relay time (01 - 99 seconds or 00 for latching). The access code programmed is stored in the keypads
internal memory.
PROGRAMMING GUIDE
• Enter the ENGINEER'S CODE: first time type six times 1 (111111
factory default) and press ENTER
will illuminate);
• Confirm ENGINEER'S CODE: re-type the same code again or
type a new code (4 to 8 digits) then press ENTER
(melody);
• Enter the code (4 to 8 digits) to enable RELAY 1 then press
ENTER
to confirm, (melody);
• Enter the RELAY 1 operation time (2 digits 01 to 99, i.e. 05 = 5
seconds, 00 = latch) then press ENTER
• Enter the code (4 to 8 digits) to enable RELAY 2 then press
ENTER
to confirm, (melody);
• Enter the RELAY 2 operation time (2 digits 01 to 99, i.e. 05 = 5
seconds, 00 = latch) then press ENTER
• Press ENTER
twice again to exit programming (melody);
• The system is ready to use (the red LED will switch OFF).
PROGRAMMING NOTES
• Pressing the ENTER
process, without changing any parameters, will exit from the
programming menu.
• When entering a relay code it must be different from the
ENGINEER'S CODE.
• To latch the relay type in the access code then press ENTER
to confirm. To unlatch the relay type in the same access code
again then press ENTER
RESETTING THE CODELOCK BACK TO FACTORY DEFAULTS
Follow the steps below to reset the codelock to factory defaults:
1. Remove/disconnect the power from the Art.4903 codelock;
2. Short out terminals - and SW2, see Fig.14;
3. Press and hold down the ENTER
down while the power is switched back ON;
4. When power is restored to the codelock wait for the module
to emit a beep and wait for the red status LED (Fig.11,
stop flashing;
5. Release the ENTER
terminals - and SW2, see Fig.15;
6. The ENGINEER'S CODE has been reset back to the factory
default, 6x1 ("111111"), relays reset to 5 seconds and internal
access codes for RLY1 and RLY2 cleared.
4000 Series GSM Audio Intercom - Technical Manual
to confirm, (the red LED
to confirm, (melody);
to confirm, (melody);
button twice during the programming
to confirm.
button and keep pressed
button then remove the short between
Press ENTER
(red LED ON)
to confirm,
Press ENTER
(melody)
Press ENTER
(melody)
Press ENTER
(melody)
Press ENTER
(melody)
Press ENTER
(melody)
Press ENTER
twice again to exit
(melody)
Fig. 14
) to
Fig. 15
- 15 -
Press 1 six times
ENTER THE
"111111"
"ENGINEER'S CODE"
(factory default)
Press 1 six times
CONFIRM
"111111" again or
OR CHANGE
type new engineer's
"ENGINEER'S CODE"
code (4 to 8 digits)
ENTER
Type code to enable
"ACCESS 1 CODE"
relay 1 (4 to 8 digits)
Two digits (01 to 99)
ENTER
i.e. 05 = 5 seconds,
"ACCESS 1 TIME"
00 = latching
ENTER
Type code to enable
relay 2 (4 to 8 digits)
"ACCESS 2 CODE"
Two digits (01 to 99)
ENTER
i.e. 05 = 5 seconds,
"ACCESS 2 TIME"
00 = latching
SYSTEM
red LED OFF
READY TO USE
66250754-EN - V1.0 - 18/02/19