Level transmitter, non-contacting radar with foundation fieldbus protocol
Hide thumbs Also See for Rosemount 5408:
Table of Contents

Advertisement

Reference Manual
00809-0300-4408
2. Apply anti-seize paste or PTFE tape on threads according to your site procedures.
3. Mount the adapter on the customer supplied flange.
4. Mount the antenna.
Rosemount 5408 Level Transmitter
H2 mm
Note
Be careful not to scratch the microwave launcher. The microwave launcher is
sensitive to mechanical impacts.
Gasket may be used as a sealant for adapters with 1½- or 2-in. BSPP (G) threads.
A. Gasket (for 1½-in. and 2-in. BSPP (G) threads only)
Note
Visually inspect the microwave launcher for damage and dirt.
Mechanical installation