Table B-3: For Divisions:
Temperature class /
Maximum surface
temperature
Division Gas groups:
T2
T3
T4
Division Dust groups:
T3
T4
T5
T6
Table B-4: For Zones:
Temperature class /
Maximum surface
temperature
Zone Gas groups:
T2
T3
T4
Zone Dust groups:
T250°C
T200°C
T135°C
T100°C
T85°C
B.8.3
IE FISCO
Certificate FM-US FM16US0010X
Standards FM Class 3600 – 2018; FM Class 3610 – 2018; FM Class 3611 – 2018; FM
Markings
Rosemount 5408 Level Transmitter
Ambient temperature range
-55 °C ≤ Ta ≤ 70 °C
-55 °C ≤ Ta ≤ 70 °C
-55 °C ≤ Ta ≤ 70 °C
-55 °C ≤ Ta ≤ 70 °C
-55 °C ≤ Ta ≤ 70 °C
-55 °C ≤ Ta ≤ 70 °C
-55 °C ≤ Ta ≤ 70 °C
Ambient temperature range
-55 °C ≤ Ta ≤ 70 °C
-55 °C ≤ Ta ≤ 70 °C
-55 °C ≤ Ta ≤ 70 °C
-55 °C ≤ Ta ≤ 70 °C
-55 °C ≤ Ta ≤ 70 °C
-55 °C ≤ Ta ≤ 70 °C
-55 °C ≤ Ta ≤ 70 °C
-55 °C ≤ Ta ≤ 70 °C
Class 3810 – 2005; ANSI/ISA 60079-0 – 2013; ANSI/UL 60079-11 – 2014;
ANSI/UL 60079-26 – 2017; ANSI/NEMA
2014; ANSI/ISA 12.27.01:2011
IS CL I, ll, lll DIV 1, GRPS A-G T4...T2
NI CL I, DIV 2, GRPS A-D T4...T2
S CL Il, lll DIV 2, GRPS E-G T4...T3
Product Certifications
Process temperature range
-55 °C to 250 °C
-55 °C to 195 °C
-55 °C to 130 °C
-55 °C to 160 °C
-55 °C to 130 °C
-55 °C to 95 °C
-55 °C to 80 °C
Process temperature range
-55 °C to 250 °C
-55 °C to 195 °C
-55 °C to 130 °C
-55 °C to 250 °C
-55 °C to 195 °C
-55 °C to 130 °C
-55 °C to 95 °C
-55 °C to 80 °C
®
250 – 1991; ANSI/IEC 60529 –