Service And Maintenance Intervals; General Info; Periodic Inspection; Tightening Bolts And Nuts - Hardi MEGA VPZ NK Original Instruction Book

Table of Contents

Advertisement

6 - Maintenance

Service and Maintenance Intervals

General Info

National or regional laws may require periodic inspection of the sprayers in use. See the following section for more details.
The subsequent periodic service and maintenance work may be carried out by the user. Contact your HARDI dealer if in
doubt. If this work is completed correctly, the sprayer will run efficiently and its lifetime will be prolonged.
When a number of hours are mentioned in this chapter, this means hours of spraying, unless otherwise explained. Operation
hours can be read in the controller in the tractor (see instruction book for controller).

Periodic Inspection

According to EU Directive 2009/128/EC regarding sustainable use of pesticides, all countries in the European Union are
obliged to inspect sprayers used for plant protection. This mandatory inspection also includes your HARDI sprayer.
The condition of the sprayer must be verified. The object of the inspection is to ensure a safe and uniform distribution of
spray liquid on the plants, as well as minimizing leaks into the environment. The inspection on your sprayer may involve
testing the condition of the pump, PTO, tanks, liquid system, measuring components, spray boom, nozzles, agitation of spray
liquid, filters, pipes and hoses.
The inspection and testing is carried out by an authorized person, who is not the owner nor the operator of the sprayer. With
a positive result, a certificate or test sticker will then show that the inspected sprayer is approved for future use. With a
negative result, the faults must be rectified to get the approval.
Check your national rules and guidelines for requirements included in this inspection as well as the interval between
inspections. For more information on how to approach this inspection, please contact your local HARDI dealer.

Tightening Bolts and Nuts

When tightening bolts and nuts as a part of periodic service or due to replacement of spare parts, it is important to apply
the correct torque. This will prevent accidents and prolong the lifetime of the parts included in the bolted joints.
If not otherwise stated in this book, please tighten bolts and nuts using the following torques.
Material: Surface treated steel
Bolt size
Recommended
(metric)
torque (Nm)
M4
2.4
M5
5
M6
8
M8
20
M10
39
M12
70
M14
112
M16
180
M18
240
M20
350
M22
490
M24
600
M27
976
M30
1300
*Exceeding this value results in a great risk of deforming the bolt.
124
Maximum torque
(Nm)*
3
6
10
25
50
85
140
215
305
435
590
750
1100
1495
Material: Stainless steel
Bolt size
Recommended
(metric)
torque (Nm)
M4
1.7
M5
3.5
M6
5.6
M8
14
M10
27
M12
49
M14
78
M16
126
M18
168
M20
245
M22
343
M24
420
M27
683
M30
910
Maximum torque
(Nm)*
2.1
4.2
7.0
17.5
35
60
98
151
214
305
413
525
770
1047

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mega vpz masterMega vpz meteor

Table of Contents