Adjustment Of 3-Way Valve; Safety Valve Activation - Hardi MEGA VPZ NK Original Instruction Book

Table of Contents

Advertisement

6 - Maintenance

Adjustment of 3-Way Valve

The large ball valve used for SmartValves and valves for filling equipment
(type s93) can be adjusted, if it is too tight to operate - or if it is too loose
(= liquid leakage).
• Correct setting is when the valve can be operated smoothly by one
hand.
Use a suitable tool and adjust the toothed ring inside the valve as shown
on the drawing.
ATTENTION! The small ball valves (type s67) cannot be adjusted.

Safety Valve Activation

To make the fluid system work perfectly over time, it is good practice to regularly provoke opening of the safety valve.
This prevents clogging and ensures proper function of the safety valve. Opening of the valve is done by turning the pressure
SmartValve to an unused function, when the pump is running. This is good practice for all sprayers; particularly for sprayers
without optional equipment.
DANGER! Before turning pressure the SmartValve to "Pressure draining", it is very important to be sure that the quick
coupler lid is correctly and completely mounted to the filling stud in its locked position. Failure to do so causes a risk
of contamination and injury from the quick coupler lid being "shot" off when pressurized! If it is not possible to mount
lid completely, lubricate the rubber seal and the grip hooks.