6 - Maintenance
50 Hours Service - Greasing the Pump
When operating the pump, it must be greased every 50 hours with 30
grams of grease into each lubrication point.
ATTENTION! In order to avoid excessive wear, it is important to
use a recommended lubricant! See the section "Recommended
Lubricants" for more information.
ATTENTION! The pump MUST be stopped during greasing!
50 Hours Service - Transmission Shaft (PTO)
1. Check function and condition of the transmission shaft protection
guard. Replace any damaged parts.
2. Lubrication. See "Lubrication and Oiling Plan - PTO" on page 142.
130