Service And Maintenance Intervals; 10 Hours Service - Suction Filter; 10 Hours Service - Cyclonefilter - Hardi RANGER 2000 Instruction Book

Table of Contents

Advertisement

Service and Maintenance intervals

10 hours service - Suction filter

To service the suction filter:
1. Pull out the steel clip (A).
2. Lift the suction hose fitting (B) from housing.
3. Filter guide and filter (C) can now be removed.
To reassemble:
4. Press the guide onto filter end.
5. Place the filter into housing with guide facing up.
6. Ensure the O-ring (D) on the hose fitting is in good condition and
lubricated.
7. Refit the suction hose (B) and steel clip (A).

10 hours service - CycloneFilter

To service the CycloneFilter:
1. Turn top Pressure Manifold valve "Off".
2. Unscrew filter lid (A).
3. Lift the lid and filter (B) from housing.
4. Separate filter from the integrated filter guide in the lid and clean
the filter.
To reassemble:
1. Grease the two O-rings on the lid/filter guide. Due to small space
at lid for example use a brush to grease with.
2. Mount the filter onto the recess (which may not be greased) in the
lid/filter guide.
3. Place the filter/filter lid into housing and screw the lid until it hits
the stop.
DANGER! Top Pressure Manifold valve must always be turned to the unused position before opening the
CycloneFilter! If not, then spraying liquid can hit you when opening the filter and drain from the tank!