Lubrication And Oiling Plan - Pto; Greasing The Pump - Hardi MEGA VPZ NK Original Instruction Book

Table of Contents

Advertisement

Lubrication and Oiling Plan - PTO

The amount of grease to be applied is mentioned in grams (g). Test your grease gun to see how many grams it supplies, for
example after 5 strokes.
ATTENTION! The correct amount of grease applied at the intervals is important. Too little or too much grease will
shorten the lifetime of the PTO.
The grease points and amount of grease to be applied are shown in the pictures below together with the intervals.
Standard PTO for tractor and sprayer
C-50
Tractor

Greasing the Pump

The pump is greased as follows:
• Factory greased:
300 g grease into each lubrication point (A).
• Normal operation:
Greasing every 50 hours with 30 grams of grease into each
lubrication point (A). See also the section"50 Hours Service"
in this book.
• After disassembling the pump (diaphragm renewal, etc.):
Greasing with 200 grams of grease into each lubrication
point (A).
ATTENTION! In order to prevent excessive wear, it is important to
use a recommended lubricant! See the section "Recommended
Lubricants" in this book.
ATTENTION! The pump MUST be stopped during greasing!
A-50
B-50
6 - Maintenance
A-50
Sprayer
C-50
123

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mega vpz masterMega vpz meteor

Table of Contents