Electrical Connections

Power Supply

Power requirement is 12 V DC. Always note the polarity!
For proper function of the electric equipment for the sprayer, the tractor
must have the following sizes of electric wires and fuses installed.
Spray box connector, 1-pin plug
The unit requires:
Wire 2.5 mm
Hydraulic control unit requires:
Wire 4.0 mm
Tractor must follow ISO 4165.
JobCom connector, 3-pin plug
The unit requires:
Wire 6.0 mm
Tractor must follow DIN 9680.
ISOBUS connector, 9-pin plug
The unit requires:
Wire 2x 10 mm
The cable is custom made and must not be
changed to another type.
Tractor must follow ISO 11783-2.
Cabin connector for grip control and Setbox:
HARDI item no. 26031500
The delivered power connectors follow the standard of most modern tractors. If you have a tractor with another power
connector, it is necessary to disassemble the connector and fit it to the actual sprayer connector. Contact your HARDI dealer.
The delivered connectors may vary on the sprayer, depending on its equipment and scope of supply.

Road Safety Kit

If rear lights are installed, connect the plug for rear lights to the tractor's
7-pin socket and check the function of rear lights, stop lights, side lights
and direction indicators on both sides before driving.
The wiring is in accordance with ISO 1724. See the chapter "Technical
Specifications" in this Instruction Book.
ATTENTION! Turn OFF all work lights when driving on public roads!
2
. Fuse 10 amps.
2
. Fuse 16 amps.
2
. Fuse 25 amps.
2
2
+ 2x 2.5 mm
+ 2x (2x 0.5 mm
Traffic light connector, 7-pin plug
The unit requires:
Wire 6x 1.5 mm
The cable is custom made and must not
be changed to another type.
Tractor must follow ISO 1724.
Power and data connector, 13-pin plug
Used for controller model HC 6500.
2
)
If needed, buy one of these tractor kits to
complete the setup:
HARDI item no. 26049400 (incl. NORAC system)
HARDI item no. 26013900 (excl. NORAC system)
Tractor must follow ISO 11446.
4 - Sprayer Setup
2
2
+ 1x 2.5 mm
.