Dynamicfluid4 Pressure Regulation - Hardi MEGA VPZ NK Original Instruction Book

Table of Contents

Advertisement

DynamicFluid4 Pressure Regulation

Traditional fluid regulation starts, when the nozzles are opened. With DynamicFluid4 (DF4), the regulation is a continuous
process, even if the nozzles are closed. A synthetic or ceramic disc and a stainless steel disc regulate the pressure and ensure
quick reaction and zero leakages. Used parameters are driving speed, PTO speed and the number of activated boom
sections. The benefit is more precise application rates from the second the sprayer begins spraying.
The DF4 system is based on 5 sensors, which feed the sprayer's computer with data necessary for optimal regulation. It auto-
primes at start-up and starts to move the regulation valve towards the final position, immediately after the operator makes
changes. For example, when section valves are opened or closed, the regulation valve is started at the same time as the
motors for the section valves are started. This prevents overpressure situations e.g. after running empty and refilling of the
main tank.
The sensors are also back-up for each other, ensuring that the system
can continue regulation - even if one or more sensor signals fails.
The applied 5 sensors measure:
1. Driving speed (km/h)
2. Pump speed (rpm)
3. Regulation valve, opening angle (degrees)
4. Fluid flow (l/min)
5. Fluid pressure (bar)
Features for DF4
• Very fast and accurate regulation when all sensors are active, setup in controller menus are correct, and pump, filters
and valves are in good condition. The system measures and calculates 20 times per second.
• Quick reacting valve, when sections are turned on/off, and at speed changes.
• Optimized AutoSectionControl feature that predict boom sections to open and optimized nozzle pressure.
• Optimized for different PTO systems.
• Nozzle surveillance. No setup or tuning is required for nozzle change.
• Controller display can show the current nozzle output, which can be compared with the rated output. A significant
difference in output is caused by failures occurring in the liquid system, such as severe clogging of filters or because of
large leakages on hoses and fittings.
• All functions work through with degraded performance (limp-home modes), if filters are cleaned.
3 - Description
53

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mega vpz masterMega vpz meteor

Table of Contents