Service And Maintenance Intervals; General Info; Tightening Bolts And Nuts - Hardi Navigator 3100 Operator's Manual

Table of Contents

Advertisement

6 - Maintenance

Service and Maintenance Intervals

General Info

National or regional laws may require periodic inspection of the sprayers in use. See the following section for more details.
The subsequent periodic service and maintenance work may be carried out by the user. Contact your HARDI® dealer if in
doubt. If this work is completed correctly, the sprayer will run efficiently and its lifetime will be prolonged.

Tightening Bolts and Nuts

When tightening bolts and nuts as a part of periodic service or due to replacement of spare parts, it is important to apply
the correct torque. This will prevent accidents and prolong the lifetime of the parts included in the bolted joints.
If not otherwise stated in this book, please tighten bolts and nuts using the following torques.
Recommended
Bolt size
torque (Ft/lb)
M4
2
M5
4
M6
6
M8
15
M10
30
M12
50
M14
85
M16
135
M18
175
M20
260
M22
360
M24
445
M27
720
M30
960
±
WARNING! Applying too little torque will result in these risks:
• bolted joints will rattle and thus fail under fatigue
• bolts are being worn quickly and thus will not fulfill their design purpose
• bolted joints will come loose
• accidents caused by assembled parts coming apart due to bolts or nuts failing or falling off.
±
WARNING! Exceeding the maximum torque will result in these risks:
• damaging or stripping the threads and deforming the fastener
• bolt heads will be broken
• bolted joints will come loose
• accidents caused by assembled parts coming apart due to bolts breaking at a later time.