13.3.3
The table below lists the available input parameters of the PZD In objects. The con-
tent of the sources depends on the application. For the different data types the
equivalent input parameters must be connected to the inverter sources.
Note:
no. of configured
PZD objects
2
In-PZD 3 Boolean
In-PZD 4 Boolean
3
In-PZD 5 Boolean
In-PZD 6 Boolean
4
In-PZD 7 Boolean
In-PZD 8 Boolean
5
In-PZD 9 Boolean
In-PZD 10 Boolean
6
In-PZD 11 Boolean
In-PZD 12 Boolean
7
In-PZD 13 Boolean
In-PZD 14 Boolean
8
In-PZD 15 Boolean
In-PZD 16 Boolean
9
In-PZD 17 Boolean
In-PZD 18 Boolean
The
1302/1303/1307/1308) is FALSE or zero.
The default setting for input parameters 1302/1303/1307/1308 is compatible to the
former CM-PDP module with:
In-PZD 3 Word
In-PZD 4 Word
In-PZD 5 Word
In-PZD 6 Word
Note:
08/08
08/08

Profibus input parameters (IN-PZD x)

The availability of In parameters depends on the number of confi-
gured PZD objects.
Every configured PZD object consists of either two Boolean, two
word or one long input parameter.
One PZD In object can be used for one data type only (depending
on the application requirements).
The first configured PZD object (mandatory) represents the PZD1/2
with fixed contents and functions.
Parameter Boolean
name
p.-no.
1300
1301
1305
1306
1310
1311
1315
1316
1320
1321
1325
1326
1330
1331
1335
1336
default
setting
for
1302 = 770 PDP absolute current
1303 = 771 PDP active current
1307 = 772 warning status
1308 = 773 error status
If one object is set to a specific source no., be sure that the corres-
ponding objects for the same location are set to their default values.
This method is the same as used with Systembus transmit objects.
Boolean inputs are representatives for boolean objects
Word inputs are representatives for current or torque objects
Long inputs are representatives for frequency or position objects
CM-PDPV1
Parameter Word
name
In-PZD 3 Word
In-PZD 4 Word
In-PZD 5 Word
In-PZD 6 Word
In-PZD 7 Word
In-PZD 8 Word
In-PZD 9 Word
In-PZD 10 Word
In-PZD 11 Word
In-PZD 12 Word
In-PZD 13 Word
In-PZD 14 Word
In-PZD 15 Word
In-PZD 16 Word
In-PZD 17 Word
In-PZD 18 Word
all
input
parameters
CM-PDPV1
Parameter Long
p.-no.
name
1302 In-PZD 3/4 Long
1303
1307 In-PZD 5/6 Long
1308
1312 In-PZD 7/8 Long
1313
1317 In-PZD 9/10 Long
1318
1322 In-PZD 11/12 Long
1323
1327 In-PZD 13/14 Long
1328
1332 In-PZD 15/16 Long
1333
1337 In-PZD 17/18 Long
1338
(except
parameters
p.-no.
1304
1309
1314
1319
1324
1329
1334
1339
33
33