13.3.3
The table below lists the available input parameters of the PZD In objects. The con-
tent of the sources depends on the application. For the different data types the
equivalent input parameters must be connected to the inverter sources.
Note:
no. of configured
PZD objects
2
In-PZD 3 Boolean
In-PZD 4 Boolean
3
In-PZD 5 Boolean
In-PZD 6 Boolean
4
In-PZD 7 Boolean
In-PZD 8 Boolean
5
In-PZD 9 Boolean
In-PZD 10 Boolean
6
In-PZD 11 Boolean
In-PZD 12 Boolean
7
In-PZD 13 Boolean
In-PZD 14 Boolean
8
In-PZD 15 Boolean
In-PZD 16 Boolean
9
In-PZD 17 Boolean
In-PZD 18 Boolean
The
1302/1303/1307/1308) is FALSE or zero.
The default setting for input parameters 1302/1303/1307/1308 is compatible to the
former CM-PDP module with:
In-PZD 3 Word
In-PZD 4 Word
In-PZD 5 Word
In-PZD 6 Word
Note:
08/08
08/08
Profibus input parameters (IN-PZD x)
•
The availability of In parameters depends on the number of confi-
gured PZD objects.
•
Every configured PZD object consists of either two Boolean, two
word or one long input parameter.
One PZD In object can be used for one data type only (depending
•
on the application requirements).
The first configured PZD object (mandatory) represents the PZD1/2
•
with fixed contents and functions.
Parameter Boolean
name
p.-no.
1300
1301
1305
1306
1310
1311
1315
1316
1320
1321
1325
1326
1330
1331
1335
1336
default
setting
for
1302 = 770 PDP absolute current
1303 = 771 PDP active current
1307 = 772 warning status
1308 = 773 error status
•
If one object is set to a specific source no., be sure that the corres-
ponding objects for the same location are set to their default values.
This method is the same as used with Systembus transmit objects.
Boolean inputs are representatives for boolean objects
•
•
Word inputs are representatives for current or torque objects
Long inputs are representatives for frequency or position objects
•
CM-PDPV1
Parameter Word
name
In-PZD 3 Word
In-PZD 4 Word
In-PZD 5 Word
In-PZD 6 Word
In-PZD 7 Word
In-PZD 8 Word
In-PZD 9 Word
In-PZD 10 Word
In-PZD 11 Word
In-PZD 12 Word
In-PZD 13 Word
In-PZD 14 Word
In-PZD 15 Word
In-PZD 16 Word
In-PZD 17 Word
In-PZD 18 Word
all
input
parameters
CM-PDPV1
Parameter Long
p.-no.
name
1302 In-PZD 3/4 Long
1303
1307 In-PZD 5/6 Long
1308
1312 In-PZD 7/8 Long
1313
1317 In-PZD 9/10 Long
1318
1322 In-PZD 11/12 Long
1323
1327 In-PZD 13/14 Long
1328
1332 In-PZD 15/16 Long
1333
1337 In-PZD 17/18 Long
1338
(except
parameters
p.-no.
1304
1309
1314
1319
1324
1329
1334
1339